Description
Overview
HYDRO BAN Quick Cure is a ready-to-use, liquid waterproofing membrane for tile and stone assemblies where a short flood-test schedule matters. Its wet-cure technology supports curing in damp, humid or cold conditions within the permitted application range. At 70°F or above, the specified two-coat sequence can allow flood testing approximately 30 minutes from the start of application.
Features
- Bonds directly to compatible metal, PVC and ABS plumbing fixtures.
- Thin cured waterproofing layer for direct-bond tile, brick or stone.
- Non-flammable, low-VOC formulation.
- Exceeds ANSI A118.10 and carries the stated TCNA Heavy Service rating.
What's Included
- One 1 gallon pail of HYDRO BAN Quick Cure.
Specifications
- Package: 1 gallon (3.8 L), item 9266-0001-2
- Approximate coverage: 134 sq. ft. per gallon for two coats
- Waterproofing thickness: Two 0.006 in. coats; 0.012 in. (0.3 mm) total
- Crack-isolation detail: Up to 1/16 in. when applied at 30 mils; follow the fabric requirements for larger gaps and transitions
- Application temperature: 40ā90°F (4ā32°C)
- Flood testing at 70°F or higher: Minimum 15 minutes after the second coat; lower temperatures require additional time
Downloads
Applications
Use in specified interior or exterior waterproofed tile assemblies, including shower pans, tub surrounds, bathrooms, laundries, pools, fountains, kitchens and countertops. The data sheet also permits terraces and balconies over unoccupied spacesānot use as the primary roof membrane over occupied rooms.
Plan Your Installation
- Prepare the approved substrate and pretreat seams, transitions and stable non-structural cracks as directed. Exterior-glue plywood is limited to appropriate interior assemblies.
- Apply two coats and check coverage/thickness with a wet-film gauge. The current instructions permit the second coat after 15 minutes and require it within one hour.
- Inspect for pinholes and repair defects before flood testing. At temperatures below 70°F, allow the stated additional 15 minutes for each 10°F drop.
- For submerged work, waterproof the continuous required assembly; coating only a pool waterline is not sufficient.
- Do not use over structural or vertically displaced cracks, in steam rooms, on exterior facades, or beneath self-leveling underlayments/decorative wear surfaces. Cover with the required traffic-bearing finish.
Common Planning Questions
Does damp-condition curing permit application at any temperature?
No. Stay within 40ā90°F and adjust cure time for lower temperatures.
Is the 0.012 in. waterproofing thickness the same as the crack-isolation detail?
No. The stated 1/16 in. crack-isolation performance requires the separate 30-mil application detail. Follow the complete instructions for the intended function.