Description
Overview
Schluter DITRA-HEAT-E-HK 240 V cable provides a flexible floor-warming layout within the DITRA-HEAT membrane. Its snap-in placement lets you heat the usable areas around fixed fixtures. Select the model for the planned coverage and electrical load; a longer cable cannot be trimmed to fit a smaller room.
Features
- Twisted-pair heating cable integrates with the membrane stud layout.
- Includes two floor-temperature sensors and approximately 7 ft. cold lead.
- Cable lengths cover a range of room sizes and heating loads.
What's Included
- One selected 240 V DITRA-HEAT-E-HK heating cable with approximately 7 ft. cold lead
- Two floor-temperature sensors
- Heating membrane and thermostat are selected separately
Specifications
- Supply voltage: 240 V
- Coverage basis in the model details: 3-stud spacing
- Cold lead: Approximately 7 ft. (2.1 m)
- Model selection: Use the selected cable's length, wattage, and amperage
Size and Model Details
- Item No.: DHE HK 240 11
- Length: 35.3 ft
- Area: 10.7 ft2
- Total Power (240 V): 135 W
- Average Power: 12.6
- Current (Amps): 0.6
- Item No.: DHE HK 240 16
- Length: 53.1 ft
- Area: 16.1 ft2
- Total Power (240 V): 203 W
- Average Power: 12.6
- Current (Amps): 0.8
- Item No.: DHE HK 240 21
- Length: 70.6 ft
- Area: 21.4 ft2
- Total Power (240 V): 270 W
- Average Power: 12.7
- Current (Amps): 1.1
- Item No.: DHE HK 240 27
- Length: 88.2 ft
- Area: 26.7 ft2
- Total Power (240 V): 338 W
- Average Power: 12.7
- Current (Amps): 1.4
- Item No.: DHE HK 240 32
- Length: 105.8 ft
- Area: 32.0 ft2
- Total Power (240 V): 405 W
- Average Power: 12.7
- Current (Amps): 1.7
- Item No.: DHE HK 240 38
- Length: 124.1 ft
- Area: 37.5 ft2
- Total Power (240 V): 475 W
- Average Power: 12.7
- Current (Amps): 2.0
- Item No.: DHE HK 240 43
- Length: 141.0 ft
- Area: 42.6 ft2
- Total Power (240 V): 540 W
- Average Power: 12.7
- Current (Amps): 2.3
- Item No.: DHE HK 240 53
- Length: 176.3 ft
- Area: 53.3 ft2
- Total Power (240 V): 675 W
- Average Power: 12.7
- Current (Amps): 2.8
- Item No.: DHE HK 240 64
- Length: 211.6 ft
- Area: 64.0 ft2
- Total Power (240 V): 810 W
- Average Power: 12.7
- Current (Amps): 3.4
- Item No.: DHE HK 240 75
- Length: 248.2 ft
- Area: 75.1 ft2
- Total Power (240 V): 950 W
- Average Power: 12.7
- Current (Amps): 4.0
- Item No.: DHE HK 240 85
- Length: 282.1 ft
- Area: 85.3 ft2
- Total Power (240 V): 1080 W
- Average Power: 12.7
- Current (Amps): 4.5
- Item No.: DHE HK 240 103
- Length: 339.4 ft
- Area: 102.7 ft2
- Total Power (240 V): 1300 W
- Average Power: 12.7
- Current (Amps): 5.4
- Item No.: DHE HK 240 129
- Length: 425.8 ft
- Area: 128.8 ft2
- Total Power (240 V): 1630 W
- Average Power: 12.7
- Current (Amps): 6.8
- Item No.: DHE HK 240 145
- Length: 480.58 ft
- Area: 145.3 ft2
- Total Power (240 V): 1840 W
- Average Power: 12.7
- Current (Amps): 7.7
- Item No.: DHE HK 240 167
- Length: 551.0 ft
- Area: 166.7 ft2
- Total Power (240 V): 2110 W
- Average Power: 12.7
- Current (Amps): 8.8
- Item No.: DHE HK 240 183
- Length: 605.9 ft
- Area: 183.3 ft2
- Total Power (240 V): 2320 W
- Average Power: 12.7
- Current (Amps): 9.7
- Item No.: DHE HK 240 204
- Length: 673.8 ft
- Area: 203.8 ft2
- Total Power (240 V): 2580 W
- Average Power: 12.7
- Current (Amps): 10.7
- Item No.: DHE HK 240 225
- Length: 744.4 ft
- Area: 225.2 ft2
- Total Power (240 V): 2850 W
- Average Power: 12.7
- Current (Amps): 11.9
Downloads
- Schluter Ditra Heat Installation Handbook
- Schluter Ditra-Heat Calculation Sheet
- Schluter Ditra-Heat Data Sheet
Applications
Choose the 240 V cable for an interior floor-warming circuit designed for that voltage.
Plan Your Installation
- Confirm that the electrical design calls for 240 V before choosing a cable from this listing.
- Calculate usable heated area around fixed fixtures and apply the spacing detail for the selected floor covering.
- Compare each model’s length and electrical load with the thermostat or power-module capacity. A different voltage or a larger room does not by itself establish the right model.
- Lay out the cold lead, sensor and heating run before covering the cable; retain the installation and testing instructions throughout the work.
Common Planning Questions
Is a 240 V cable interchangeable with the 120 V version?
Order the voltage required by the circuit and control design; these are separate cable selections.
Can leftover heating cable be shortened?
No. Select the length from the layout before purchase and keep the factory cable intact.
Cable Planning and Installation Limits
- Never cut, shorten, cross, or modify the heating cable. Altering it can cause overheating or failure.
- Do not run heating cable beneath fixed cabinets, islands, vanities, tub platforms, or other permanent fixtures.
- Keep the factory cold-lead/heating-cable splice entirely beneath the floor covering; do not place it in the wall.
- Use the spacing specified for the selected floor assembly. The coverage figures in Specifications use 3-stud spacing, approximately 3-1/2 in. (9 cm); alternate approved layouts change the heated area.
- Maintain the installation clearances: 8 in. from other heat sources, 6 in. from plumbing drains, 3 in. from walls, and 2 in. from fixed cabinets, subject to the applicable handbook detail.
- Plan a permitted buffer area for remaining cable, such as near the doorway or behind a toilet. Never shorten a cable to resolve a layout problem.