EasyMat is a lightweight tile-and-stone underlayment that provides bonded crack prevention and impact-sound reduction over acceptable floors. The mat cuts with a utility knife and is available here in two non-peel-and-stick roll configurations for mortar-applied installation.
Features
- Up to 25 times lighter than 1/4-inch backerboard; no mechanical fasteners or seam tape needed for the specified installation.
- Designed for supported in-plane subfloor movement up to 1/4 in.
- Can serve as a thermal break beneath compatible floor-heating systems.
What's Included
- One roll in the selected thickness and length: SGL12 or SGL5.
Specifications
- SGL12 option: 12 mm; 4 × 30 ft.; 120 sq. ft.
- SGL5 option: 5 mm; 4 × 75 ft.; 300 sq. ft.
- Thermal resistance: R-1.8 for 12 mm; R-0.8 for 5 mm, per ASTM C518
- Sound test improvement: 23 for 12 mm; 20 for 5 mm under cited impact test
- Overall assembly rating: Up to IIC 71 / STC 72 includes the tested floor and ceiling construction, not the mat alone
Size Options
- 4' x 30' x 12MM - 120 Sq. Ft.
- 4' x 75' X 5MM - 300 Sq. Ft.
Downloads
Applications
Use beneath residential or light-commercial tile and stone floors over suitable concrete, cement backerboard or properly built wood assemblies. Choose the thickness for the floor build-up and required tested performance, not simply for roll area.
Selection and Use
- Both listed MPNs, SGL12 and SGL5, are the standard non-peel-and-stick versions. The manufacturer’s optional self-adhesive version is a different configuration.
- The mat is not for vertical or differential crack movement and cannot correct structural deflection.
- Contact CUSTOM for mosaics smaller than 4 × 4 in. or dimensional stone larger than 12 × 12 in.; wood and gypsum assemblies need their specified preparation.
- Sound performance depends on the entire floor/ceiling assembly. Do not interpret IIC 71 as a 71-dB reduction supplied by this roll.
- Do not leave exposed as a wear surface. Exterior decks, post-tensioned concrete and heated floors require the applicable technical details.